= Textbook =
<div style="float:right; font-size:90%;">
[https://openstax.org/books/university-physics-volume-2/pages/9-introduction University Physics Volume 2: Chapter 9]
  [[Courant_et_resistance|🌐 Version en français : Courant et résistance]]
</div>


= Current and Resistance =
<!-- Page intro banner -->
== Theory ==
<div style="border-left:5px solid #0ea5e9; padding:1em; background-color:#ecfeff; margin:0.75em 0 1em;">
  <p style="margin:0; font-weight:bold;">📘 Current and Resistance</p>
</div>


=== Current and Current Density ===
= Reference Textbook =
Electric current (<math>I</math>) is the flow of electric charge through a conductor, measured in amperes (<math>A</math>). The current density (<math>\vec{J}</math>) represents the current per unit cross-sectional area, expressed as:
<math>\vec{J} = \frac{\vec{I}}{A} = \sigma \vec{E}</math>
where <math>\sigma</math> is the conductivity, and <math>\vec{E}</math> is the electric field.


<div style="border:1px solid #28a745; padding:0.8em; background-color:#f0fdf4; margin:1em 0;">
  <p style="margin:0.2em 0;"><strong>📖 Reference Textbook:</strong><br>
  [https://openstax.org/books/university-physics-volume-2/pages/9-introduction University Physics Volume 2: Chapter 9 — Current and Resistance]</p>
</div>


<youtube>FViTaHwLgxo</youtube>
= Theory =
<youtube>1ahlvmI_0HU</youtube>


=== Resistance, Resistivity, and Conductivity ===
== Electric Current ==
Resistance (<math>R</math>) quantifies the opposition to the flow of current in a conductor, measured in ohms (<math>\Omega</math>). Resistivity (<math>\rho</math>) is a material property that measures resistance per unit length and cross-sectional area. Conductivity (<math>\sigma</math>) is the inverse of resistivity.


<math>R = \rho \frac{L}{A}, \quad \sigma = \frac{1}{\rho}</math>
'''Electric current''' is the rate at which electric charge passes through a cross section:


where <math>L</math> is the length of the conductor and <math>A</math> is its cross-sectional area.
<math>I=\frac{dq}{dt}</math>


<youtube>FFHUoWFtab0</youtube>
For a constant current, <math>I=\Delta q/\Delta t</math>. The SI unit is the '''ampere''' (A):
<youtube>IWTyLsvQmxE</youtube>


=== Ohm's Law ===
<math>1~\mathrm{A}=1~\mathrm{C/s}</math>
Ohm's Law relates the voltage (<math>V</math>), current (<math>I</math>), and resistance (<math>R</math>) in a circuit:
<math>V = IR</math>


It also applies at the microscopic level:
<math>\vec{E} = \rho \vec{J}</math>


<youtube>nmA7xmXwXqg</youtube>
=== Conventional Current Direction ===
 
The '''conventional current direction''' is the direction in which positive charges would move. In a metal, the mobile charge carriers are electrons, so their drift is '''opposite''' to the conventional current direction.
 
Inside a resistor, conventional current flows from higher to lower electric potential, in the direction of the electric field.
 
<br class="clear"/>
 
== Current Density and Drift Speed ==
 
The '''current density''' <math>\vec{J}</math> describes the current per unit area and points in the direction of conventional current. Its SI unit is <math>\mathrm{A/m^2}</math>.
 
For a uniform current density perpendicular to a cross section of area <math>A</math>, the magnitudes satisfy
 
<math>J=\frac{I}{A}</math>
 
 
For one type of charge carrier,
 
<math>\vec{J}=nq\vec{v}_{\mathrm{d}}</math>
 
where:
 
* <math>n</math> is the number of mobile charge carriers per unit volume (in <math>\mathrm{m^{-3}}</math>);
* <math>q</math> is the charge of each carrier (in coulombs, C);
* <math>\vec{v}_{\mathrm{d}}</math> is their average '''drift velocity''' (in <math>\mathrm{m/s}</math>).
 
For electrons, <math>q=-e</math>, where <math>e=1.602\times10^{-19}~\mathrm{C}</math>. In terms of magnitudes,
 
<math>J=nev_{\mathrm{d}},\qquad I=neAv_{\mathrm{d}}</math>
 
Electron drift speeds in ordinary wires can be very small, of order <math>10^{-5}</math> to <math>10^{-4}~\mathrm{m/s}</math>, depending on the current density and material. This slow average drift is distinct from the much faster propagation of an electrical signal through a circuit.
 
<div style="border-left:5px solid #ef4444; padding:0.8em 1em; background-color:#fff7f7; margin:1em 0;">
'''▶ Video: Current and Current Density — 1'''
 
[https://www.youtube.com/watch?v=FViTaHwLgxo Watch the video on YouTube]
</div>
 
<div style="border-left:5px solid #ef4444; padding:0.8em 1em; background-color:#fff7f7; margin:1em 0;">
'''▶ Video: Current and Current Density — 2'''
 
[https://www.youtube.com/watch?v=1ahlvmI_0HU Watch the video on YouTube]
</div>


<br class="clear"/>
<br class="clear"/>
==== Ohm's Law Simulation ====
*[https://phet.colorado.edu/en/simulations/ohms-law Ohm's Law on PhET] <br>


Back to [[Electricity_and_Magnetism]]
== Conservation of Charge ==
 
Electric charge is conserved. Charge does not accumulate in a wire or at a junction. Therefore, the current is the same at every cross section of an unbranched wire, even if its cross-sectional area changes.
 
At a junction, the total current entering equals the total current leaving:
 
<math>\sum I_{\mathrm{in}}=\sum I_{\mathrm{out}}</math>
 
Equivalently, <math>\sum I=0</math> when entering and leaving currents are assigned opposite signs. This is '''Kirchhoff's junction rule''', used in [[Notes on DC Circuits|DC circuit analysis]].
 
<br class="clear"/>
 
== Resistance, Resistivity, and Conductivity ==
 
'''Resistance''' <math>R</math> describes how strongly a component opposes current. It is the ratio of the voltage across the component to the current through it:
 
<math>R=\frac{V}{I}</math>
 
Here, <math>V</math> denotes the magnitude of the potential difference across the resistor, and <math>I</math> denotes the current magnitude. The SI unit of resistance is the '''ohm''':
 
<math>1~\Omega=1~\mathrm{V/A}</math>
 
'''Resistivity''' <math>\rho</math> is a material property, measured in <math>\Omega\cdot\mathrm{m}</math>. For a uniform wire of length <math>L</math> and constant cross-sectional area <math>A</math>,
 
<math>R=\rho\frac{L}{A}</math>
 
A longer wire has a larger resistance; a thicker wire has a smaller resistance, for the same material under the same conditions. Resistivity depends on the material and conditions such as temperature.
 
'''Conductivity''' <math>\sigma</math> is the reciprocal of resistivity:
 
<math>\sigma=\frac{1}{\rho}</math>
 
 
<div style="border-left:5px solid #ef4444; padding:0.8em 1em; background-color:#fff7f7; margin:1em 0;">
'''▶ Video: Resistance, Resistivity, and Conductivity — 1'''
 
[https://www.youtube.com/watch?v=FFHUoWFtab0 Watch the video on YouTube]
</div>
 
<div style="border-left:5px solid #ef4444; padding:0.8em 1em; background-color:#fff7f7; margin:1em 0;">
'''▶ Video: Resistance, Resistivity, and Conductivity — 2'''
 
[https://www.youtube.com/watch?v=IWTyLsvQmxE Watch the video on YouTube]
</div>
 
<br class="clear"/>
 
== Ohm's Law ==
 
An '''ohmic''' component has a current proportional to the applied voltage. Its resistance remains constant when physical conditions, particularly temperature, are held constant:
 
<math>V=IR</math>
 
Its current–voltage graph is a straight line through the origin. Not all components obey Ohm's law: for a non-ohmic component, the ratio <math>V/I</math> may vary with the applied voltage.
 
For an ohmic material, the microscopic form of Ohm's Law is
 
<math>\vec{E}=\rho\vec{J},\qquad \vec{J}=\sigma\vec{E}</math>
 
 
<div style="border-left:5px solid #ef4444; padding:0.8em 1em; background-color:#fff7f7; margin:1em 0;">
'''▶ Video: Ohm's Law'''
 
[https://www.youtube.com/watch?v=nmA7xmXwXqg Watch the video on YouTube]
</div>
 
<br class="clear"/>
 
== Electrical Power and Energy ==
 
As charge passes through a resistor, electric potential energy is converted into thermal energy. If <math>V</math> is the voltage drop and <math>dq</math> is the amount of charge passing through, the energy transferred to the resistor is equal to the negative of the change in electric potential energy: <math>dU=-V\,dq</math>.
 
'''Power''' is the rate of energy transfer, so here, the magnitude of the power is:
 
<math>P=\frac{dU}{dt}=V\frac{dq}{dt}=VI</math>
 
The SI unit is the '''watt''' (W):
 
<math>1~\mathrm{W}=1~\mathrm{J/s}</math>
 
Using <math>V=IR</math>, the power dissipated by a resistor can also be written as
 
<math>P=I^2R=\frac{V^2}{R}</math>
 
For constant power over a time interval <math>\Delta t</math>, the energy transferred is
 
<math>Energy_{\mathrm{transferred}}=P\Delta t</math>
 
=== What Is a Kilowatt-Hour? ===
 
A '''kilowatt-hour''' (kWh) is a unit of '''energy'''. It is the energy transferred by a device operating at a power of 1 kW for 1 hour:
 
<math>1~\mathrm{kWh}=1000~\mathrm{W}\times3600~\mathrm{s}=3.6\times10^6~\mathrm{J}</math>
 
For example, a 2 kW heater operating continuously for 3 hours uses 6 kWh of electrical energy.
 
<br class="clear"/>
 
= Current and Resistance Simulations =
 
* [https://phet.colorado.edu/en/simulations/ohms-law PhET: Ohm's Law] — Explore the relationship between voltage, current, and resistance.
 
<br class="clear"/>
 
<!-- Bottom navigation menu -->
<div style="float:left; font-size:90%; margin:0.25em 0 0.75em 0;">
  [[Capacitors|⬅ Previous: Capacitors]]
</div>
 
<div style="float:right; font-size:90%; margin:0.25em 0 0.75em 0;">
  [[Notes on DC Circuits|Next: DC Circuits ➡]]
</div>
 
<br style="clear:both;" />

Latest revision as of 11:09, 3 October 2026

 ⬅ Back to Electricity and Magnetism


 🌐 Version en français : Courant et résistance

📘 Current and Resistance

Reference Textbook

📖 Reference Textbook:
University Physics Volume 2: Chapter 9 — Current and Resistance

Theory

Electric Current

Electric current is the rate at which electric charge passes through a cross section:

I=dqdt

For a constant current, I=Δq/Δt. The SI unit is the ampere (A):

1A=1C/s


Conventional Current Direction

The conventional current direction is the direction in which positive charges would move. In a metal, the mobile charge carriers are electrons, so their drift is opposite to the conventional current direction.

Inside a resistor, conventional current flows from higher to lower electric potential, in the direction of the electric field.


Current Density and Drift Speed

The current density J→ describes the current per unit area and points in the direction of conventional current. Its SI unit is A/m2.

For a uniform current density perpendicular to a cross section of area A, the magnitudes satisfy

J=IA


For one type of charge carrier,

J→=nqv→d

where:

  • n is the number of mobile charge carriers per unit volume (in m−3);
  • q is the charge of each carrier (in coulombs, C);
  • v→d is their average drift velocity (in m/s).

For electrons, q=−e, where e=1.602×10−19C. In terms of magnitudes,

J=nevd,I=neAvd

Electron drift speeds in ordinary wires can be very small, of order 10−5 to 10−4m/s, depending on the current density and material. This slow average drift is distinct from the much faster propagation of an electrical signal through a circuit.

▶ Video: Current and Current Density — 1

Watch the video on YouTube

▶ Video: Current and Current Density — 2

Watch the video on YouTube


Conservation of Charge

Electric charge is conserved. Charge does not accumulate in a wire or at a junction. Therefore, the current is the same at every cross section of an unbranched wire, even if its cross-sectional area changes.

At a junction, the total current entering equals the total current leaving:

∑Iin=∑Iout

Equivalently, ∑I=0 when entering and leaving currents are assigned opposite signs. This is Kirchhoff's junction rule, used in DC circuit analysis.


Resistance, Resistivity, and Conductivity

Resistance R describes how strongly a component opposes current. It is the ratio of the voltage across the component to the current through it:

R=VI

Here, V denotes the magnitude of the potential difference across the resistor, and I denotes the current magnitude. The SI unit of resistance is the ohm:

1Ω=1V/A

Resistivity ρ is a material property, measured in Ω⋅m. For a uniform wire of length L and constant cross-sectional area A,

R=ρLA

A longer wire has a larger resistance; a thicker wire has a smaller resistance, for the same material under the same conditions. Resistivity depends on the material and conditions such as temperature.

Conductivity σ is the reciprocal of resistivity:

σ=1ρ


▶ Video: Resistance, Resistivity, and Conductivity — 1

Watch the video on YouTube

▶ Video: Resistance, Resistivity, and Conductivity — 2

Watch the video on YouTube


Ohm's Law

An ohmic component has a current proportional to the applied voltage. Its resistance remains constant when physical conditions, particularly temperature, are held constant:

V=IR

Its current–voltage graph is a straight line through the origin. Not all components obey Ohm's law: for a non-ohmic component, the ratio V/I may vary with the applied voltage.

For an ohmic material, the microscopic form of Ohm's Law is

E→=ρJ→,J→=σE→


▶ Video: Ohm's Law

Watch the video on YouTube


Electrical Power and Energy

As charge passes through a resistor, electric potential energy is converted into thermal energy. If V is the voltage drop and dq is the amount of charge passing through, the energy transferred to the resistor is equal to the negative of the change in electric potential energy: dU=−Vdq.

Power is the rate of energy transfer, so here, the magnitude of the power is:

P=dUdt=Vdqdt=VI

The SI unit is the watt (W):

1W=1J/s

Using V=IR, the power dissipated by a resistor can also be written as

P=I2R=V2R

For constant power over a time interval Δt, the energy transferred is

Energytransferred=PΔt

What Is a Kilowatt-Hour?

A kilowatt-hour (kWh) is a unit of energy. It is the energy transferred by a device operating at a power of 1 kW for 1 hour:

1kWh=1000W×3600s=3.6×106J

For example, a 2 kW heater operating continuously for 3 hours uses 6 kWh of electrical energy.


Current and Resistance Simulations

  • PhET: Ohm's Law — Explore the relationship between voltage, current, and resistance.


 ⬅ Previous: Capacitors
 Next: DC Circuits ➡